WARNING | |
HAZARDOUS VOLTAGE (120V) CONTACT MAY CAUSE ELECTRICAL SHOCK AND INJURY. DISCONNECT POWER BEFORE SERVICING. |
-
Remove the top panel from the back of the Bevi.
- Loosen the 6 screws in the corners of the panel.
- Lift the panel up to unhook from the screws, and remove.
- Place the panel to the side.
-
Remove the center panel from the back of the Bevi.
- Loosen the 4 screws in the corners of the panel.
- Lift the panel up to unhook from the screws, and remove.
- Place the panel to the side.
-
Locate and Inspect the CO2 Sense connection.
- The CO2 Sense connector is at the bottom, far right side of the BUC Board.
- Verify that the connector is fully seated in the BUC Board.
- Visually inspect the connector and wires for any damage along the entire cable between the BUC Board and the CO2 pressure sensor.
- Carefully disconnect, and reconnect the CO2 Sense cable.
- Ensure the cable fully clicks into the connector on the BUC Board.
-
Repeat the Diagnostic Test
- If the test passes, continue with Installation.
- If the test continues to fail, please contact Bevi Support at 866-704-2384