Overview/Before beginning:
This article provides instructions for sanitizing the Bevi Countertop after receiving a “Sanitation Required” alert, following periods of low or no usage, or as needed. It is important to keep the Bevi clean for quality and food safety requirements, as well as to maintain a great customer experience with each beverage dispense.
In this article (click to jump):
- Task 1: Prepare the Sanitization solution
- Task 2: Sanitize Flavor Lines
- Task 3: Ensure the Ice Bank is full
- Task 4: Flush the Filter and Buffer Tank
- Task 5: Clean the Console/Head Unit
- Task 7: Log any additional service completed.
Required Tools & Parts
- Recommended: V1.5 Flavor Line Cleaning Manifold - (P/N #720-0231)
- 1 packet Chlorine-Based Sanitizer - (from 5-PACK: P/N #720-0144)
- 5 gallon bucket
- Spray Bottle
- Microfiber Towels
- Cleaning brushes
- Glass Cleaner
- Cleaning/Sanitary Gloves (Nitrile or similar)
- #2 Phillips Screwdriver
- 1 Liter Container
-
OPTIONAL: Sanitation Kit - (P/N #720-0169)
- One sanitation kit can clean up to 10 Bevi machines. The kit includes the following: -1x collapsible bucket, -12x microfiber towels, -1x spray bottle, -10x chlorine based sanitizer packets, -1x compressed air duster, and -3x cleaning brushes.
- With this kit, you will still need the V1.5 Flavor Line Cleaning Manifold, and glass cleaner separately.
ℹ️ NOTE: If a flavor line cleaning manifold (P/N #720-0231) is not on-hand, the flavor lines can still be sanitized individually, one-at-a-time. However, we strongly recommend saving time by using the cleaning manifold/sanitation tool to allow all 4 lines to be sanitized at once.
Task 1: Prepare the Sanitization solution
- Before starting, put on sanitary gloves.
- In the 5 gallon bucket, prepare the chlorine-based sanitizer solution.
- Fill the bucket with 3 gallons of hot water.
- Dissolve one 1-oz. packet of Chlorine Sanitizer in the hot water.
- Once dissolved, dip your spray bottle into the bucket to fill the bottle.
- This will be used to clean various areas of the Bevi.
- Leave the remaining sanitizer in the bucket until finished as you will use this to soak certain parts of the Bevi.
Task 2: Sanitize Flavor Lines
- On the screen, enter the Service Panel.
- Touch the Service icon, then “Start Service”, and enter PIN code: “1986”
- Disconnect all 4 flavor connectors from the flavor boxes.
- Leave the flavor boxes in their respective slots to avoid reinstalling them incorrectly.
- Disconnect each flavor connector from the flavor lines.
- Disconnect the push-to-connect fittings on the connectors from the 1/4” tubing.
- Place all 4 flavor connectors into the bucket of sanitizer solution.
- Allow the flavor connectors to soak in the solution for a minimum of 1 minute.
- While flavor connectors soak, use a cleaning brush to thoroughly clean each connector.
- Connect the Flavor Line Cleaning Manifold to each of the flavor lines.
- Ensure the 1/4” flavor line is fully seated into the push-to-connect fittings.
- Place the open ends of the Flavor Line Cleaning Manifold tubing into the bucket with sanitizer solution.
- From the Service Panel screen, prime each flavor line with sanitizer solution.
- Press and hold the “Prime” button for 30 seconds for each flavor.
- Allow sanitizer solution to sit in the flavor lines for a minimum of 2 minutes.
- While waiting for flavor lines to sit with sanitizer solution, remove the drip tray from the front of the head unit.
-
- Bring to nearest sink and dump out any excess liquid.
- Disassemble the drip tray by removing the metal grate.
- Place drip tray components into the bucket with sanitizer solution.
- Allow to soak in solution for a minimum of 1 minute.
-
.
- Remove the open end of the Flavor Line Cleaning Manifold tubing from the bucket of sanitizer solution.
- Allow any excess fluid to drain into the bucket.
- Remove flavor connectors and drip tray from the bucket.
- Thoroughly rinse all components with hot water.
- Thoroughly scrub and clean the drip tray.
- Empty out the bucket of sanitizer solution.
- Thoroughly rinse any remaining sanitizer solution out.
- Refill the bucket with clean, hot water.
- Place the Flavor Line Cleaning Manifold tubes into the bucket with clean, hot water.
- While holding a container under the nozzle prime all 4 flavor lines for 1 minute and 20 seconds each to thoroughly flush with hot water.
- Disconnect the Flavor Line Cleaning Manifold, and reconnect all 4 flavor connectors to the flavor lines.
- Ensure the 1/4” flavor tubing is fully seated into the push-to-connect fittings.
- Reconnect each connector to its associated flavor box.
- Ensure that each line is connected to the correct flavor.
- Prime all the flavors.
- While holding a container under the nozzle, prime all flavor lines for 15 seconds each to evacuate any remaining clean water and prime with flavor concentrate.
Task 3: Ensure the Ice Bank is full
- Turn off the water supply to the Bevi machine.
- Press the back arrow at the top left corner of the Service Panel
- Dispense Still water to depressurize the water line.
- Remove the open end of the overflow tube from the clips on the front of the chiller and drain any water that is in the tube.
- Once drained, you can remove the overflow tube from the chiller to thoroughly rinse it out.
- Reinstall the overflow tube.
- Connect water supply to the ice bank fill on the chiller.
-
For newer Front Connection style chillers: (All inputs and outputs located on the front):
- Disconnect the water in line, and transfer over to the ice bank fill fitting.
- Disconnect the water in line, and transfer over to the ice bank fill fitting.
-
For older Top Connection chillers (Outputs coming from the top of the chiller):
- The water in and ice bank fill connections are on the back of the chiller.
- Carefully slide the chiller and tray out of the cabinet and place on the floor.
- *If there is enough space in the cabinet, you may be able to carefully rotate the chiller to access the fittings on the back.
- Disconnect the water in tube, and transfer over to the ice bank fill fitting.
-
For newer Front Connection style chillers: (All inputs and outputs located on the front):
- With the open end of the overflow tube draining straight down into a bucket or container, turn on the water supply to begin topping off the ice bank.
- Fill the ice bank until water begins to flow from the overflow tube.
- As soon as water is flowing from the tube, turn off the water supply.
- Allow any excess water to drain from the tube, and resecure the open end of the tube into the clips.
- Disconnect the water line from the ice bank fill, and reconnect to the water in fitting.
- If removed, reinstall the chiller into the cabinet.
Task 4: Flush the Filter
- Turn off the water supply to the Bevi.
- Disconnect the water line from the filter output.
- With the open end of the tube running into the bucket, turn on the water supply.
- Flush 3 gallons of water through the filter.
- Once complete, turn off the water supply.
- Reconnect the water line.
- Turn on the water supply.
Task 7: Clean the Head Unit
-
SPRAY/WIPE DISPENSE AREA
- Spray down the dispense area with sanitizer and wipe clean with a microfiber towel.
- Once the dispense area is clean, reinstall the drip tray.
-
WIPE DOWN HEAD UNIT
- Thoroughly wipe down the entire outside of the head unit.
- Clean any water or flavor concentrate that has collected around the base of the head unit.
-
CLEAN TOUCHSCREEN
- Using glass cleaner and a clean microfiber towel, wipe down the touchscreen to remove any residue and fingerprints.
Task 8: Log any additional service completed.
- Clear the Sanitation Required alert.
- Mark the alert as resolved.
- Enter initials and save.
- If flavors and enhancements, CO2 tank, or Filter need to be replaced during service, ensure they are logged appropriately.
If you have any questions or need further assistance, please contact Bevi Technical Support
at support@bevi.co, or call our support line at 866-704-2384
(866-704-BEVI)