This guide details requirements and a check list (checklist) before installing a Countertop Bevi. Below is a quick summary of the install requirements:
Item |
Requirement |
Water supply |
- 1x 3/8” outer diameter water line with local shut off valve (minimum water pressure of 50 PSI and 5 liters per minute flow rate)
|
Power supply |
|
Internet connection |
- Wireless or Ethernet connection is required to enable the smart functions of Bevi
- Cellular modem is available for sites without access to wireless or Ethernet. OptConnect cellular modem can be ordered from Bevi.
|
Interior cabinet dimensions to store under counter Bevi components |
-
Layout option 1, utilizing two cabinets (recommended):
- Cabinet 1 – 28” tall, 16.25” wide, 24” deep (minimum req.)
- Cabinet 2 – 28” tall, 18” wide, 24” deep (minimum req.)
-
Layout option 2, utilizing one cabinet:
- Cabinet 1 – 28” tall, 34.25” wide, 24” deep (minimum req.)
|
Head unit hole for hot air outlet
|
- 1x 4” in diameter, with minimum of 5” in distance from back wall to edge of the drilled hole.
- NOTE: The head unit must sit over the hole. Otherwise, the hot air will not be properly vented outwards.
|
Ventilation holes for fresh air inlet |
- To allow for sufficient fresh inlet airflow, the cabinet where the carbonator is installed must have cutouts in the bottom of cabinets or added door vents. The cutouts or door vents must have a minimal combined surface area of 12.5 in^2.
|