Pre-Installation Requirements
Water Source
- Dedicated 1/4” plumbing line
- Minimum supply pressure of 40 PSI and 2.5 liters per minute flow rate
- Maximum water inlet supply pressure of 80 PSI
Power Source
- 110–120 VAC, 60 Hz, 12 A max current draw.
- GFCI protected 3-prong outlet.
Internet Source
Ensure one of the following is available on site:
- WiFi 802.11b/g/n (2.4 GHz)
- Ethernet Connection (RJ-45)
- Cellular Reception
Upright Storage
- The Standup 2.0 can be turned on immediately if shipped upright. If it was not shipped upright, it should be stored in an upright position for at least 4 hours before being powered on.
- See How to transport or ship the Standup 2.0 (Final-Mile Only)
Space Requirements
To provide adequate ventilation, the Standup 2.0 requires 1" clearance on each side, 2" clearance in the back, and 3" clearance on the top. This means the minimum total space required for the Bevi Standup 2.0
is:
- Width Required: 18.5"
- Depth Required: 24"
- Height Required: 69.25"
Machine is for indoor use only, 10-32°C (50-90°F).