Who can use this article?
Technicians who are inflating (recharging) a Standup 2.0 buffer
tank
using this pump model.
Overview
This article provides additional support for operating the Bevi-recommended buffer tank inflation pump, for use while performing the recharge procedure for Standup 2.0 buffer tanks. The pump may vary slightly in color or exact appearance from these photos.
Visit the link below to view the guide for the Standup 2.0 buffer tank recharge procedure.
Buffer Tank Recharge Guide, SU 2.0 ↗
In this article (click to jump):
Guide
1. Power On / Off
- Turn On: Press and hold the Power Button for 3 seconds.
- Turn Off: Press and hold the Power Button for 3 seconds again.
- Auto Shutoff: The pump turns off after 3 minutes of inactivity or when the battery is low.
2. Check Battery Level & Charge
-
Battery Indicator Colors:
- Green: 60–100% charged (Use the pump only at this level)
- Yellow: 30–60% charged
- Red: 10–30% charged
-
To Charge:
- Use the included USB-C cable and a 5V/2A adapter.
- Indicator flashes while charging and turns solid green when full.
- The pump cannot be used while charging.
⚠️ Important: Always charge the pump until the indicator is green before use to ensure reliable inflation.
3. Make Sure Pump is in the Right Mode
- Press the Mode Button until you are in Custom Mode (or any mode that allows manual PSI adjustment).
- The Working Mode Indicator will show the current mode.
-
Tip: Custom Mode gives you full control over the target PSI setting.
4. Make Sure Unit Is in PSI
- Press the Unit Button until the display shows PSI.
5. Set Target Pressure to 22.0 PSI
- Use the + / – Buttons to set the target pressure to 22.0 PSI.
6. Connect and Inflate
- Connect the hose to the Schrader valve on the buffer tank.
- Press the Inflate Button once to start inflation.
- The pump will automatically stop when it reaches 22 PSI