Required Tools
- Phillips Screwdriver (#2)
Before Continuing
During the Install Diagnostics test, the filter should not be installed, and water and CO2 should not yet be turned on. If these steps have already been done:
- Turn off water supply
- Turn off the CO2 tank by rotating the handle clockwise until it stops.
- Drain the Buffer tank.
Troubleshooting Steps
Task 1: Repeat the Diagnostic Test
- Verify water and CO2 are turned off, and filter is NOT installed.
- Restart the diagnostic tests to see if it passes on the second attempt.
- If the test continues to fail, power cycle the Bevi via the power switch on the front of the chiller.
- Navigate back through the installation steps to the Install Diagnostic step and repeat the test.
- If the test continues to fail, continue to Task 2.
Task 2: Power Off the Bevi.
- Power off the Bevi using the power switch on the front of the chiller.
- Disconnect the power cord from the back of the chiller.
Task 3: Remove the chiller from the cabinet.
- Carefully lift the front of the chiller so the locating tabs on the bottom can come up and out of the ventilation holes.
- Slide the chiller forward so the front hangs over the edge of the cabinet.
- Remove the red locking clip and disconnect the 3/8” water supply line from the back of the chiller.
- This step may not be necessary if there is enough slack on the water line to fully remove the chiller without putting tension on the tubing.
- Lifting from the front and the rear grab handle, carefully lift the chiller out of the cabinet and place on the floor.
Task 4: Remove the top panel.
- Using a #2 Phillips screwdriver, loosen the two screws securing the top panel of the chiller.
- With the screws fully loosened, lift the front of the panel up, and slide forward to release the rear locating tabs.
- Place the panel to the side.
Task 5: Remove the PCB panel.
- Using a #2 Phillips screwdriver, loosen the two screws securing the PCB panel on the left side of the chiller.
- With the screws fully loosened, lift the panel to release the lower locating tab and remove.
- Place the panel to the side.
Task 6: Inspect the Chiller Temperature Sensor Connection.
- Locate the Chiller Temp sensor on the top of the ice bank.
- Trace the white cable back to the connector.
- Inspect the Chiller Temp Sensor cable.
- Confirm that the sensor is connected to the Chiller Sensor harness.
- Inspect the wires and connector for any visible damage or loose pins.
- If there is any damage to the cable or connector, please contact Bevi Support at 866-704-2384.
- Gently disconnect, and reconnect the Chiller Temp Sensor.
- There is a lock latch on the connector that needs to be depressed to disconnect the cable.
- When reconnecting, ensure the connector is fully seated and clicks into place.
Task 7: Inspect the Chiller Sensor Harness Connection.
- In the PCB panel, locate the Chiller Sense Harness on the BUC Board.
- Inspect the Chiller Sense harness.
- Confirm that the sensor harness is connected to the BUC Board.
- Inspect the wires and connector for any visible damage or loose pins.
- If there is any damage to the cable or connector, please contact Bevi Support at 866-704-2384.
- Gently disconnect, and reconnect the Chiller Sense Cable.
- There is a lock latch on the connector that needs to be depressed to disconnect the cable.
- When reconnecting, ensure the connector is fully seated and clicks into place.
Task 8: Reinstall the Chiller.
- Reinstall the top panel, and the PCB panel.
- Take care not to pinch any wiring in the panels.
- Ensure the locating tabs slot into place
- Tighten the screws to secure the panel.
- Reconnect the chiller power cord.
- Carefully lift the chiller into place in the cabinet.
- Ensure the locating tabs on the bottom of the chiller fit into the ventilation holes and the chiller sits flush on the base of the cabinet.
- If it was disconnected during removal, reconnect the 3/8” water supply tube.
- Ensure the tubing is fully seated into the push to connect fitting.
- Reinstall the red locking clip.
- Power on the chiller.
Task 9: Repeat the Diagnostic Test
- Once the Bevi starts up, continue through the Install Wizard back to the diagnostics step.
- Rerun the test.
- If the test passes, continue with Installation.
- If the test continues to fail, please contact Bevi Support at 866-704-2384