Required Tools & Parts
- Key or similar thin/flat tool
- PN #112808-01 - CABLE - USB COMMS FROM HEAD UNIT CONTROL BOARD TO SBC-SOM (optional)
- FRU PN #720-0370 - HEAD UNIT CONTROL BOARD (optional)
- FRU PN #720-0371 - COMPUTER BOARD
Troubleshooting Steps
Task 1: Retest
- Restart the diagnostic tests to see if it passes on the second attempt.
-
If the test continues to fail, power cycle the Bevi via the power switch on the front of the chiller.
- Navigate back through the installation steps to the Install Diagnostic step and repeat the test.
- If the test continues to fail, continue to Task 2.
Task 2: Power Off the Bevi.
- Power off the Bevi using the power switch on the front of the chiller.
- Disconnect the power cord from the back of the chiller.
Task 3: Remove the head unit shell.
- Power off the Bevi using the power switch on the front of the Compact Chiller.
-
Release to top mounting clip for the head unit shell.
- Place both hands on the sides of head unit shell near the top.
- Using some force, twist the top of the shell to release the top clip.
-
Inside the cabinet, locate the split nut on the threaded coupler at the base of the head unit and loosen it 2-3 turns.
- This will allow you to rotate the head unit for easier access to the back.
Task 4: Check for HUCB Heartbeat LED.
- Plug in the power cord and power on the the Bevi via the switch on the front of the Compact Chiller.
-
Check and confirm that the Heartbeat LED is present on the HUC Board.
- The Heartbeat LED should be blinking GREEN/RED.
- If Heartbeat LED is present, continue to Task 5.
-
If Heartbeat LED is not present, or is not blinking GREEN/RED, contact Bevi Support at 866-704-2384.
- Bevi Support will assist in confirming that the HUCB on the latest firmware version.
-
If the firmware is out of date, Bevi Support will push a remote update.
- Once updated, restart the diagnostics test.
- If the test passes, continue with installation.
-
If the HUCB is already on the latest firmware version, but there is still no Heartbeat LED, the HUCB may be faulty.
- FRU PN #720-0370 - HEAD UNIT CONTROL BOARD
Task 5: Inspect the USB-C cable at HUC Board.
- Power off the Compact Chiller and disconnect the power cable.
- Locate the USB-C connection on the HUC board.
- Inspect the cable and connector for any visible signs of damage.
- Ensure the cable is fully seated.
- If any damage to the cable or connector is found, please contact Bevi Support at 866-704-2384.
-
Carefully disconnect the cable from the HUC board,
- Inspect the connector and cable for any damage or wear.
-
Reconnect the USB-C end of the cable to the HUC Board.
- Ensure the cable is fully seated into the board side connector.
Task 6: Inspect the USB-A cable at SBC.
- Locate the right angle USB-A connection on the SBC board.
- Inspect the cable and connector for any visible signs of damage.
- Ensure the cable is fully seated.
- If any damage to the cable or connector is found, please contact Bevi Support at 866-704-2384.
-
Carefully disconnect the USB-A end of the cable from the SBC.
- Inspect the connector and cable for any damage or wear.
-
Reconnect the USB-A end of the cable to the SBC.
- Ensure the cable is fully seated into the board side connector.
Task 7: Retest
- Plug in the power cord and power on the Bevi via the switch on the front of the Compact Chiller.
- Navigate back to the Install Diagnostics screen.
-
Restart the Install Diagnostics test.
-
If the test passes, continue with installation.
- Reinstall the head unit shell, and retighten the split nut.
-
If the test fails, either the USB cable, SBC, or HUC Board may be faulty.
- PN #112808-01 - CABLE - USB COMMS FROM HEAD UNIT CONTROL BOARD TO SBC-SOM (optional)
- FRU PN #720-0370 - HEAD UNIT CONTROL BOARD (optional)
- FRU PN #720-0371 - COMPUTER BOARD
-
If the test passes, continue with installation.
If you need any further assistance, please contact Bevi Technical Support at support@bevi.co, or call our support line at 866-704-2384 (866-704-BEVI).