Overview
This guide provides a step-by-step process of swapping the Nozzle Shroud in a Countertop 2.0 head unit.
In this article (click to jump):
- Required Tools & Parts
- Remove and Replace Procedure
- Task 1: Remove the Nozzle Shroud
- Task 2: Install the New Nozzle Shroud
- Task 3: Test the Nozzle Shroud
Required Tools & Parts
- 720-0382 - FRU - NOZZLE SHROUD, BLACK
- Container
Remove and Replace Procedure
Task 1: Remove the Nozzle Shroud
- Remove the nozzle shroud.
- Identify the tab extending downward from the nozzle shroud and pull on the tab until the nozzle shroud releases from the front housing.
- Dispose of the old nozzle shroud.
Task 2: Install the New Nozzle Shroud
- Orient the new nozzle shroud such that the pull tab is away from you and pointing toward the back of the head unit.
- Push the nozzle shroud up and into the nozzle and LED opening.
- The nozzle shroud will snap into place.
- Press your finger along the perimeter of the nozzle shroud to seat it into the nozzle and LED opening.
- Visually inspect the installation of the nozzle shroud.
- The nozzle shroud should be flush against the nozzle and LED opening.
- All eight flavor injectors should be visible from the underside of the nozzle shroud.
- A correctly installed nozzle shroud is pictured below.
- Examples of incorrect installations are pictured below.
CAUTION: Ensure all eight injectors are visible, otherwise concentrate will dispense inside the head unit!
- If the nozzle shroud installation fails visual inspection, remove the nozzle shroud from the nozzle and LED opening and attempt to reinstall it.
Task 3: Test the Nozzle Shroud
- Navigate to the Service Panel.
- Touch the service icon in the upper left corner.
- Touch "Start Service"
- Enter the PIN to access the service panel.
- Enter Troubleshooting Tools
- Touch the “Flavor and Enhancements” dropdown menu.
- Hold a container directly under the nozzle.
- Prime each flavor line for a short period of time to ensure the flavor injectors are not obstructed by the nozzle shroud.
- Exit out of the service menus and put the CT 2.0 back on the dispense UI.