Overview
This guide provides a step-by-step process of swapping a BiB connector fitting in a Countertop 2.0 head unit’s flavor line.
In this article (click to jump):
- Required Tools & Parts
- Remove and Replace Procedure
- Task 1: Power Off the Bevi
- Task 2: Disconnect the Flavor Box
- Task 3: Remove the Old Fitting
- Task 4: Replace the Fitting
- Task 5: Prime the Flavor Line
Required Tools & Parts
- 720-0394 - FRU - FLAVOR LINE BIB TO PUMP
- Tube cutter
- Box cutter
Remove and Replace Procedure
Task 1: Power Off the Bevi
- Power off the Bevi using the power switch on the front of the chiller.
- Disconnect the power cord from the back of the chiller.
Task 2: Disconnect the Flavor Box
- Open the cabinet and locate the flavor box that corresponds to the fitting that is being replaced.
- Turn the threaded connector counter clockwise to disconnect from the box.
Task 3: Remove the Old Fitting
- Remove the fitting from the BiB connector.
- Depress the push-to-connect fitting on the threaded BiB connector.
- Pull on the fitting with the push-to-connect depressed to remove it from the BiB connector.
- Set the threaded BiB connector to the side.
- Use the tube cutters to cut the flavor line slightly above the BiB connector fitting.
- Ensure the cut is made on the flavor line above the fitting.
- Take care not to remove too much flavor line from the head unit.
- Dispose of the old BiB connector fitting.
Task 4: Replace the Fitting
- Remove the flavor line from the new fitting.
- The FRU contains both a flavor line and the fitting.
- Use a box cutter to cut the flavor line away from the new fitting.
- Take care not to cut into the new fitting.
- Insert the new fitting into the flavor line using a twisting and pushing motion.
- Ensure the flavor line is fully seated on the new fitting.
- Insert the fitting into the threaded BiB connector.
- Ensure the fitting is fully seated in the push-to-connect fitting in the threaded BiB connector.
- Use the groove on the fitting to gauge if it is fully seated in the connector.
Task 5: Prime the Flavor Line
- Reinstall the flavor connector onto the flavor box.
- Turn the threaded connector clockwise until it is hand tight.
- Ensure the connector is seated flush.
- Plug in the power cord and power on the Bevi.
- Navigate to the Service Panel.
- Touch the service icon in the upper left corner.
- Touch "Start Service"
- Enter the PIN to access the service panel.
- Navigate to Troubleshooting Tools
- Touch the ‘Alerts and Maintenance’ button.
- Touch the ‘Troubleshooting Tools’ button.
- Touch the ‘Flavors and Enhancements’ menu.
- A drop down menu will open up.
- Identify the flavor pump to be primed.
- Hold a container directly under the nozzle.
- When priming, only flavor concentrate is dispensed.
- Flavor may come out at an angle.
- Press the relevant button to prime the flavor line.
- Allow the prime cycle to run all the way through.
- If no flavor is dispensed:
- Double check the connection between the flavor box and the threaded connector.
- Confirm you can hear the pump running.
- Double check the tubing connections on the pump, if they are reversed flavor will not dispense.